ECONOTERM® for a 20 t/h Steam Boiler


      The ECONOTERM® unit presented in the photograph is designed to preheat the feeding water for a 20 t/h steam boiler installed in a Romanian furniture factory. The system has been operating since 1997.

 

 

 

The main features are:

      • Inlet hot flue gases temperature: 180 °C.
      • Outlet hot flue gases temperature: 120 °C.
      • Inlet water temperature: min. 10 °C.
      • Outlet water temperature: 97 °C.
      • Heat recovered: 730,000 w.
      • Total number of heat pipes: 965 pieces.
      • Material of the heat pipes: carbon steel pipe ø 28 x 2,5 mm.
      • Total length of the heat pipe: 2,000 mm.
      • Overall dimensions: 2,300 x 2,100 x 700 mm (connection pieces are not included).

Patented. See List of Patents.

 



      With extensive experience in designing customized solutions for ECONOTERM® heat recovery units, TRANSTERM® offers this system for improving the efficiency of any kind of Boilers.
      Please call for details. For information on how to contact us please click here.